Eligibility Criteria:


We offer loans for Users and Producers of technologies which improve water and energy use and improved land management.

Eligible borrowers are:

·         Private micro, small and medium enterprises registered and operating primarily in the Republic of Tajikistan.

·         Have between 9 and 249 employees.

·         Maximum annual turnover / balance sheet total up to EUR 50,000,000

·         Producers of climate resilient equipment, materials and technology.

·         Suppliers and installers of climate resilient equipment, materials and technology.


Eligible Projects:


Projects must be in compliance with all applicable national environmental, social and health and safety legislation of Tajikistan.

Typical projects may include:

·         Modernisation of production machinery;

·         Replacement of boilers in heating systems;

·         Refurbishment of water pipes, pumps, taps and distribution systems;

·         Installation of water recycling system;

·         Installation of rainwater harvesting system;

·         Implementation of energy saving measures through the insulation of buildings,  replacing windows,

          doors, heating and lighting systems.


Please select your preferred technology below:


  Approved Eligible Technologies-ENERGY


Code

Technology

Sub-technology

Performance Criteria

Supplier/Installer 

A1

Windows

Double-glazing type window, Triple-glazing type window

Thermal transmittance (U-value)[W/m2K] <1.4 W/m2K

Rohat plast
Karin Mann 130
91 919 2222
www.rohatplast.tj

A1

Windows

Double-glazing type window, Triple-glazing type window Thermal transmittance (U-value)[W/m2K] <1.4 W/m2K

Romsar
Fuchik street
37 221 2323
www.romsar.tj
info@romsar.tj

A1

Windows

Double-glazing type window, Triple-glazing type window

Thermal transmittance (U-value)[W/m2K] <1.4 W/m2K

http://tajbao.tj/search

A2

Insulation

Rockwool and glasswool,
XPS, EPS Sprey Polyurethane,
Foam, Glass Foam, Ceramic Wool,
Aerated concrete panel,
Polyethylene foam,

For buildings:
Performance

Jaljam Bazaar Criterion
for walls= U <0.6 W/m2K;
Performance Criterion
for roof= U<0.5 W/m2K

Jaljam Bazaar
Dushanbe

A2

Insulation

Rockwool and glasswool,
XPS, EPS Sprey Polyurethane,
Foam, Glass Foam, Ceramic Wool,
Aerated concrete panel,
Polyethylene foam,
For buildings:
Performance Criterion
for walls= U <0.6 W/m2K;
Performance Criterion
for roof= U<0.5 W/m2K

Penoblok Zafar
900081810
www.somon.tj/aid/94701/ 

A2

Insulation

Rockwool and glasswool,
XPS, EPS Sprey Polyurethane,
Foam, Glass Foam, Ceramic Wool,
Aerated concrete panel,
Polyethylene foam,
For buildings:
Performance Criterion
for walls= U <0.6 W/m2K;
Performance Criterion
for roof= U<0.5 W/m2K

Isolation foam
Zebuniso 5, near DOC
'225 1111, 93 741 2222

A2

Insulation

Rockwool and glasswool,
XPS, EPS Sprey Polyurethane,
Foam, Glass Foam, Ceramic Wool,
Aerated concrete panel,
Polyethylene foam,

For buildings:
Performance Criterion
for walls= U <0.6 W/m2K;
Performance Criterion
for roof= U<0.5 W/m2K

http://tajbao.tj/search

B2

Biomass Boilers


Boiler efficiency > 70%


B3

Domestic Air Conditioner Units


Coefficient of Performance (COP) >3.0


C1

Heat pumps

Ground source heat pumps, water source heat pumps, air source heat pumps

For ground source and water source heat pumps:
Coefficient of Performance (COP)>3.5
For air source heat pumps:
Coefficient of Performance (COP)>3.0


Clint via Max Piccini
Rivignano (UD) 11/13, 33050, Italy
+39 0432 823011
www.clint.it
info@clint.it

C2

Central Chillers

Package Air or Water Cooled Chillers

Coefficient of Performance (COP)>3.0

Clint via Max Piccini
Rivignano (UD) 11/13, 33050, Italy
+39 0432 823011
www.clint.it
info@clint.it

C3

Absorption Chillers

Single Stage absorption
chillers, Two Stage absorption chillers

For Single Stage absorption chillers:
Coefficient of Performance (COP)>0.6
For Two Stage absorption chillers:
Coefficient of Performance (COP)>1.0

Clint via Max Piccini
Rivignano (UD) 11/13, 33050, Italy
+39 0432 823011
www.clint.it
info@clint.it

C4

Ventilation

Mechanical Building entilation - Air Handling Units (AHUs)

AHUs only with heat recovery and
Variable Speed Drive (VSD) installed


Komil
Dushanbe
90 094 0997

C5

Central Heating

Boilers, burners, Heat
exchangers

For boilers:
-  Gas boilers: Minimum
   85% conversion efficiency
-  For biomass boilers:
   Minimum 70%
   conversion efficiency
For burners:
   Only double stage and
   modulation burners
For Heat exchangers:
   No performance
   requiremet

Komil
Dushanbe
90 094 0997

C5

Central Heating

Boilers, burners, Heat
exchangers

 For boilers:
-  Gas boilers: Minimum
   85% conversion efficiency
-  For biomass boilers:
   Minimum 70%
   conversion efficiency
For burners:
   Only double stage and
   modulation burners
For Heat exchangers:
   No performance
   requiremet

Clint via Max Piccini
Rivignano (UD) 11/13, 33050, Italy
+39 0432 823011
www.clint.it
info@clint.it

D1

Lamps

Compact florescent lamps, Tube florescent lamps, High Intensity Discharge (HID) Lamps, LEDs

Efficiency factor for Compact florescent lamps: 60 lm/W
Efficiency factor for Tube florescent lamps: 80 lm/W
Efficiency factor for HID Lamps: 70 lm/W
Efficiency factor for LEDs: 60 lm/W


D2

Fixtures

Fixtures

No performance requirement


D3

Automatic Control

Lighting control and automation systems

No performance requirement


E1

Air compressors

Screw air compressor,
Centrifugal air compressor,
Reciprocating air compressor

Maximum energy consumption: 115 Wh/Nm3

LLC "Mega-Com"
Glibochitskaya 33/37, Kiev
(044) 461-99-79/78
(044) 462-58-51
http://fiac-ua.com/
opt1@min.com.ua

F1

Transformers

Single or 3 phase dry type transformers

Maximum losses according to EU directives

LLC "Elga"
Shaulyay
+370 41 594 710
www.elga.su
Info@elga.lt

F1

Transformers

Single or 3 phase dry type transformers Maximum losses according to EU directives

LLC "Diaz"-Muzaffarov Dilshod
Aini 46-61
+(372) 2270806
www.tj.all.biz/elektroobor
udovanie-g177#.VgJuLd-qqko 

F2

Electrical Compensation system

Compensation System No performance requirement

LLC "Elga"
Shaulyay
+370 41 594 710
www.elga.su
Info@elga.lt

F2

Electrical Compensation system

Compensation System No performance requirement

LLC "Diaz"-Muzaffarov Dilshod
Aini 46-61
+(372) 2270806
www.tj.all.biz/elektroobor
udovanie-g177#.VgJuLd-qqko 

G1

Comprehensive Facility and
Monitoring Control System

Custom process automation, software,
hardware including sensors and analyzers
No performance requirement

Adopen
Borbad 36
918 918 918

H1

Electrical motors

Low-voltage three-phase motors type, Variable Speed Drives (VSD)

For Low-voltage three-phase motors type:
IE2 Class electric motor or higher
For Variable Speed Drives (VSD):
No performance requirement


H2

Fans

Centrifugal type fan,
Axial type fan

Centrifugal type fan,
Axial type fan    IE2 Class electric motor or higher

LLC "Aircon"-Kamolov M
Rudaki 137, Hisor Murodov
90 104 99-11
dushanbe.flagma-tj.com/ru/344443/

H2

Fans

Centrifugal type fan,
Axial type fan

Centrifugal type fan,
Axial type fan    IE2 Class electric motor or higher

LLC "Tajik climate"-
Sobirov D.Logistics
Loik Sherali 3
93 560 01-06
dushanbe.flagma-tj.com/ru/317851/

H2

Fans
Centrifugal type fan,
Axial type fan
Centrifugal type fan,
Axial type fan    IE2 Class electric motor or higher

LLC "Difad"-Mirzoev S.
Telman 14
+992 372 24 72-70
+992 918 75 38-33
dushanbe.flagma-tj.com/ru/126694/

H3

Pumps Water Circulation pumps IE2 Class electric motor or higher

LLC "Aircon"-Kamolov M.
Rudaki 137, Hisor Murodov C/C
+992 90 104 99-11
dushanbe.flagma-tj.com/ru/344443/

H3

Pumps Water Circulation pumps IE2 Class electric motor or higher

LLC "Tajik climate"-Sobirov D.Logistics
Loik Sherali 3
+992 93 560 01-06
dushanbe.flagma-tj.com/ru/317851/

H3

Pumps Water Circulation pumps IE2 Class electric motor or higher

LLC "Difad"-Mirzoev S.
Telman 14
+992 372 24 72-70
+992 918 75 38-33
dushanbe.flagma-tj.com/ru/126694/

H4

Elevators High efficient elevators IE2 class motor and Variable Speed Drive (VSD)


I1

Solar PV Crystalline panels, thin film panels For crystalline panels: 12% panel efficiency
For thin film panels: 10% panel efficiency


I2

Solar water heaters Flat panels, Vacuum tube types 70% conversion factor


I3

Biomass/Biogas for thermal energy production


70% boiler efficiency


I4

Solar dryers
No performance criteria


I5

Solar verandas
No performance criteria



Eligible Technologies - WATER


Code

Technology

Sub-technology

Criteria

Supplier/Installer 

A1

Household equipment

Refurbishment of water distribution system

-    Water meter
Water efficient fittings:
-    Faucets: Residential
    (Mixer+pressure reducer)
-    Basins (only to fit mixer)
-    Showerhead: (pressure
     breaker  handset + mixer)
-    Tank toilets: 2bottom flush;
-    Bath max 150 l
-    Filter
Piping:
-    Polyethylene pipes (PE
     based) for cold and
     hot water pipes

http://tajbao.tj/search

B1

Water re-use / grey water recycling system


-    Water collected from Toilet
     Sink or  Bath or washing
     machine
-    Water is not diverted from
     kitchen or toilet plumbing.
-    Water re-used only fortoilet
     & gardens
-    Overflow to sewer
-    Max volume 50 l
-    Back flow protection: Air
     GAP
-    Pipe: Pipe carrying gray
     water
     to be coloured


B2

Rainwater harvesting


-    Minimum volume: 15m3



Non-approved technologies can also be funded under CLIMADAPT, but we need to assess these projects one by one. Additionally we can finance other water/energy/land saving projects for which your preferred technology is not listed if the projects can meet 10% saving criteria.

  Non-Approved Eligible Technologies-ENERGY


Code

Technology

Sub-technology

Criteria

Supplier/Installer 

X

Energy Supply and
Renewable Energy Technologies

Mini/Small Hydro Power Plants,

No performance criteria


X

Energy Supply and
Renewable Energy Technologies

Wind Power Plants,

No performance criteria


X

Energy Supply and
Renewable Energy Technologies

Biogas for electricity production,

No performance criteria


X

Energy Supply and
Renewable Energy Technologies

Combine Heat and Power (CHP)



X

Energy Supply and
Renewable Energy Technologies

Geothermal Power Plants         



X

Modernization of production machinery

Sector Specific Production machine modernization and renovation

Efficient production of process machinary




Eligible Technologies - WATER



Code

Technology

Sub-technology

Criteria

Supplier/Installer 

X

Disaster control measures

Flooding prevention measures



X

Modernization of production machinary

Efficient production of process machinary